LED BLUE PHOSPHOR SOLUTIONS

Premium Blue Phosphor
for UV LED & Biomedical

Complete blue phosphor portfolio featuring UV-excitable aluminate series and upconversion fluoride phosphor for UV-LED lighting, display backlighting, anti-counterfeiting, and biomedical fluorescence applications.

2+
Product Series
450nm
Pure Blue Output
51.7nm
Narrow FWHM
7μm
Precision D50
Industry Challenges

Blue Phosphor Application Challenges

Understanding the key technical challenges in UV-LED and biomedical applications

Color Purity

Achieving pure blue output with narrow bandwidth is critical for display color gamut. Wide FWHM results in color bleeding and poor saturation.

UV Chip Compatibility

Standard phosphors designed for blue chips don't perform well under UV excitation. Specialized UV-optimized phosphors are required for 360-390nm chips.

Biomedical Sensitivity

Traditional fluorescence suffers from high background noise. Upconversion phosphors with NIR excitation offer superior signal-to-noise ratio.

Particle Size Control

Consistent particle size distribution is essential for uniform dispensing and coating. Tight D50 tolerance ensures batch-to-batch reproducibility.

Product Portfolio

Complete Blue Phosphor Series

From UV-excitable aluminate to upconversion fluoride, meeting all lighting and biomedical requirements

DL-450UV — UV-Excitable Aluminate Blue

360-390nm UV excitation · 450nm pure blue output · Narrow 51.7nm FWHM

ModelPeak λFWHMD50CIE Coord.Excitation
DL-450UV450±1nm51.7nm7±0.5μm(0.1447, 0.0636)360-390nm UV
DL-450UV
Peak λ450±1nm
FWHM51.7nm
D507±0.5μm
CIE(0.1447, 0.0636)
DL-450UV Blue Phosphor

DL-450UV features narrow 51.7nm FWHM for excellent color purity in UV-LED applications

Key Performance Data

450nm
Peak Wavelength
51.7nm
FWHM (Narrow)
360-390nm
UV Excitation
7±0.5μm
Particle D50
Aluminate Material Advantage

Aluminate crystal structure provides: excellent UV excitation efficiency optimized for 360-390nm chips, narrow bandwidth (51.7nm FWHM) for high color purity, white powder appearance for easy process control, and 12-month shelf life under proper storage conditions.

Engineer's Recommendation

DL-450UV is specifically designed for UV LED chips (360-390nm). Its narrow 51.7nm FWHM delivers excellent color purity ideal for high color gamut displays. For blue chip (450-460nm) applications, consider YAG or LD series yellow/green phosphors instead. The tight D50 tolerance of 7±0.5μm ensures consistent dispensing performance.

LD-980-B — Upconversion Fluoride Blue

980nm NIR excitation · 478nm blue emission · Ultra-fine 7μm particles

ModelPeak λTypeD50Powder ColorExcitation
LD-980-B478±1nmUpconversion7±0.5μmWhite980nm NIR
LD-980-B
Peak λ478±1nm
TypeUpconversion
D507±0.5μm
Excitation980nm NIR
LD-980-B Upconversion Phosphor

LD-980-B upconversion phosphor converts 980nm NIR to 478nm blue light with minimal background interference

Key Performance Data

478nm
Blue Emission
980nm
NIR Excitation
7μm
Ultra-fine D50
>100:1
Signal/Noise Ratio
Upconversion Technology Advantage

Fluoride-based upconversion mechanism provides: minimal background interference — NIR excitation avoids biological autofluorescence, deep tissue penetration — NIR light penetrates several millimeters into tissue, excellent photostability — resistant to photobleaching for long-term observation, and low phonon energy (~350 cm⁻¹) for high upconversion efficiency.

Engineer's Recommendation

LD-980-B is ideal for biomedical fluorescence labeling, immunoassays, and anti-counterfeiting applications. The 7μm ultra-fine particles offer excellent dispersibility for bio-conjugation. For biological applications, surface modification (PEG, carboxyl, amino groups) is recommended to improve water solubility and biocompatibility. Standard excitation uses 980nm NIR laser at 0.1-10 W/cm² power density.

FeatureDL-450UVLD-980-B
Material SystemAluminateFluoride
Excitation Wavelength360-390nm UV980nm NIR
Emission Wavelength450nm478nm
Emission TypeDown-conversionUpconversion
FWHM51.7nm (Narrow)
Particle Size D507±0.5μm7±0.5μm
Background NoiseNormalExtremely Low
Best ApplicationsUV-LED, Display, Anti-fakeBiomedical, Sensors
DL-450UV vs LD-980-B
MaterialAluminate vs Fluoride
Excitation360-390nm UV vs 980nm NIR
Emission450nm vs 478nm
TypeDown-conversion vs Upconversion

Need Custom Surface Modification?

Our engineers can provide customized surface modification services including carboxylation, amination, PEG coating, and bio-conjugation protocols for your specific application requirements.

Why Choose Us

Key Advantages

What sets our blue phosphors apart from the competition

Dual Technology Platform

Both down-conversion (UV-excitable) and upconversion (NIR-excitable) blue phosphors — one supplier for all your blue emission needs.

Precision Particle Control

Tight D50 tolerance of 7±0.5μm ensures consistent dispensing, coating uniformity, and batch-to-batch reproducibility.

Narrow Bandwidth Option

DL-450UV delivers 51.7nm FWHM — excellent color purity for high color gamut display applications.

Custom Modification Service

Surface functionalization, bio-conjugation protocols, and excitation system design support for biomedical applications.

Applications

Where Our Blue Phosphors Excel

Proven performance across demanding lighting, display, and biomedical applications

UV-LED Lighting

UV-LED Lighting

UV-LED general illumination, specialty lighting, and curing indicator lights. DL-450UV delivers pure blue under 360-390nm UV chip excitation.

Display Backlighting

Display Backlighting

LCD backlight modules, wide color gamut displays, and specialty visual systems requiring high color purity blue emission.

Anti-Counterfeiting

Anti-Counterfeiting & Security

Currency verification, document authentication, high-security labels, and invisible watermarks with UV-excitable blue phosphor.

Biomedical Detection

Biomedical Detection

Immunoassays, cell labeling, tissue imaging, and molecular detection. LD-980-B upconversion offers superior signal-to-noise ratio.

Fluorescent Probes

Fluorescent Probes & Sensors

Environmental monitoring, chemical sensing, temperature detection, and biosensors utilizing upconversion luminescence.

Research & Analysis

Research & Analysis

Fluorescence microscopy, flow cytometry, spectral analysis standards, and materials science research applications.

Free Sample Available

Test Before You Commit

Request a free phosphor sample kit to evaluate spectral performance, particle distribution, and process compatibility in your production environment.

Ships in 3 business days
50-100g per sample
COA included
Quality Assurance

Consistent Quality You Can Trust

Strict quality control ensures batch-to-batch consistency

ISO 9001 Certified
RoHS Compliant
REACH Compliant
10+ Years Experience

Every batch undergoes rigorous testing using fluorescence spectrometer and laser particle size analyzer. We guarantee CIE color coordinate deviation ≤0.003 and particle size variation ≤5% between batches. All products come with detailed COA and full traceability. Aluminate phosphors are moisture-sensitive — proper sealed storage at ≤25°C, ≤60%RH is recommended.

Get Started

Ready to Enhance Your Application?

Contact us for free consultation and samples

Free Application Design

Our engineers help design optimal phosphor selection and excitation system for your target application requirements

Free Sample Testing

Evaluate spectral performance, particle distribution, and process compatibility before volume orders

Fast Delivery

50-100g samples shipped worldwide within 3 business days with tracking

24h Response

Dedicated technical support team responds within 24 hours to all inquiries

Phone+86-731-8888666
Request Free Sample Talk to Engineer

Engineers will reply within 24 hours

Note: All technical data comes from standard fluorescence spectrometer and laser particle size analyzer testing. Aluminate phosphors (DL-450UV) are moisture-sensitive — store in sealed containers at ≤25°C, ≤60%RH. Fluoride upconversion phosphors (LD-980-B) should avoid strong acids/bases (pH 6-8 recommended). Contact our engineers for professional application solution design.